The microcontroller-based valve control HE 5711 is used for the cycle control of electromagnetic valves in industrial dust filter systems. The flexible design concept enables use as astandard rail version or as a control unit in a dust-tight Makrolon housing with ATEX Zone 22 approval. The controller automatically detects the number of solenoid valves connected. The cleaning processes are time-controlled – for this purpose, the pulse and pause times are set via potentiometers. After the end of normal cleaning, the control system can carry out post-cleaning if desired.
Applications
Bunker top filter, industrial vacuum cleaner
Technical data
Technische Daten
Versorgung
100 – 240 V AC, 50 – 60 Hz
Option: 24 V DC ± 10% [Sicherheitskleinspannung SELV]
Leistungsaufnahme
30 VA, Eigenverbrauch ca. 3 W
LEDs
4 × für Ventilansteuerung, rot
RUN [Betrieb], grün
PULSE [Puls], gelb
PAUSE [Pause], gelb
TEST [Test], grün
Bedienelemente
Taster TEST [Test]: Das nächste Ventil wird angesteuert
PULSE [Puls]: Pulszeit-Einstellung
Potenziometer von 0,02 – 1,2 s
PAUSE [Pause]: Pausenzeit-Einstellung
Potenziometer von 1 – 270 s